The unit in brief

Lesson Description

Every working aquaponics tank slowly turns more acidic, because nitrification releases acid week after week. In pH Tug-of-War, students find out what can pull the pH back. They learn the pH scale, compare a digital pH pen with a liquid kit, and fair-test store-bought crushed coral as a buffer. Then they work out how much the system needs and design a buffer plan for the class tank. All acid tests happen in cups, away from the fish.

Planning details

Lesson at a Glance

Grade level

8

Duration

2 weeks, 4 sessions, 50 minutes each (options for 60 or 75)

Format

5E (Engage, Explore, Explain, Elaborate, Evaluate)

Driving question

Our tank keeps getting more acidic. What can pull the pH back, and how much do we need?

NGSS standards

MS-PS1-2, MS-ETS1-1, MS-ETS1-2, MS-ETS1-3

Math

CCSS 8.EE.A.3 (powers of 10), 8.SP.A.1 (plots and patterns)

HĀ outcomes

All six: Belonging, Responsibility, Excellence, Aloha, Total Well-being, Hawaiʻi. Each session names an HĀ Focus.

System

Classroom aquaponics system; tests run in cups of tank water

Pairs with

Atom Shuffle (comes first)

Hands-on activities

What Students Will Do

✓Read the tank’s pH record and learn why each step on the scale is a tenfold change.

✓Compare a digital pH pen with a liquid kit.

✓Watch acid react with calcium carbonate.

✓Set up a fair test: tank water with and without crushed coral.

✓Read the two-day results, compare four coral doses and do the buffer math.

✓Graph the results against the target band and write a Claim–Evidence–Reasoning paragraph.

✓Draft a buffer plan for the class tank and pitch the final version.

Hawaiʻi connection

The Oʻahu Connection

Coral is calcium carbonate, and it is protected here. Hawaiʻi law restricts taking sand, dead coral and coral rubble from the shoreline, so the unit uses only store-bought aquarium substrate and nothing is collected from a beach or reef. The same chemistry that steadies the tank also links to ocean acidification, which students can connect to the reefs around their own island.

4 sessions

Sessions

01

The Slow Slide

02

Acid Meets Coral

03

How Much Is Enough?

04

Hold the Line

Prep and supplies

What You’ll Need

  • The classroom aquaponics system and about a month of its pH readings
  • A digital pH pen that reads to 0.1, with calibration solutions
  • A liquid pH kit or strips
  • About 1 cup of store-bought crushed coral or aragonite
  • White vinegar, droppers or 1 mL syringes, clear cups, measuring spoons and mesh bags
  • Goggles for every student

Students never add anything to the fish system. Any real change to the tank is made by the teacher.

References

Sources

  • Somerville, C., et al. (2014). Small-Scale Aquaponic Food Production, FAO Fisheries and Aquaculture Technical Paper 589 (manipulating pH). fao.org
  • Deer, Dunn, Hu and Dusci (2021). Nitrification and Maintenance in Media Bed Aquaponics, HLA-6729. Oklahoma State University Extension.
  • California Water Environment Association. How Alkalinity Affects Nitrification. cwea.org
  • Sallenave, R. Important Water Quality Parameters in Aquaponics Systems, Circular 680. New Mexico State University.
  • Hawaiʻi Revised Statutes §171-58.5, Prohibitions (sand, dead coral, coral rubble). capitol.hawaii.gov
  • NGSS Lead States (2013). Next Generation Science Standards: MS-PS1, MS-ETS1. nextgenscience.org
  • Hawaiʻi Board of Education Policy E-3, Nā Hopena Aʻo (HĀ). boe.hawaii.gov